07

2023

-

06

Common Faults and Troubleshooting Methods for Fully Automatic Screw-Capping and Sealing Machines

Author:

Administration Department – Li Yuanyuan


Fault 1: The machine cannot start normally.

Fault Cause Analysis:

1. The emergency stop or overload protection switch has not been reset;

2. Circuit failure;

3. Motor damage.

Suggested exclusion method:

1. Reset the relevant device;

2. Please have a professional appliance repair technician inspect it.

3. Replace the motor.

Fault No. 2: The capping effect at the machine head is poor.

Fault Cause Analysis:

1. The magnetic force of the machine head is too weak;

2. The magnetic force at the machine head is too strong, causing the bottle caps to deform.

Suggested exclusion method:

1. You can adjust the magnetic force adjustment sleeve at the head of the machine to increase the magnetic force and observe the sealing effect.

2. Adjust the magnetic adjustment sleeve at the machine head to reduce the magnetic force of the head and observe the sealing effect.

Fault 3: Overload failure.

Fault cause analysis: The limit switch is damaged or improperly positioned.

Recommended exclusion method: Replace or adjust.