12

2023

-

06

Common Faults of Weighing and Filling Machines and Their Troubleshooting Methods

Author:

Administration Department – Li Yuanyuan


Fault 1: The machine cannot start normally.

Fault Cause Analysis:

1. The emergency stop switch has not been reset;

2. Circuit malfunction;

3. Motor damage.

Suggested exclusion method:

1. Reset the emergency stop switch;

2. Please have a professional appliance repair technician inspect it.

3. Replace the motor.

Fault No. 2: Inaccurate filling capacity.

Fault cause analysis: Is the electromagnetic weighing sensor malfunctioning?

Fault 3: Frequent breakdowns and shutdowns.

1. Failure Cause Analysis:

2. The bottle wheel does not match the bottle;

3. The conveyor speed is mismatched;

4. The overload switch below the bottle wheel is installed too high.

5. The overload spring is too loose.

Suggested exclusion method:

1. Replace with a matching bottle-picking wheel;

2. Adjust the bottle conveyor speed;

3. Adjust the clearance to 0.5 millimeters and tighten the spring.

Fault 4: No filling.

Suggested exclusion method:

1. Check whether all electrical components are functioning properly.

2. Check whether the inlet and outlet check valves are properly open or closed.

Fault 5: Overload failure.

Fault Cause Analysis: Limit switch damaged or improperly positioned.

Recommended exclusion method: Replace or adjust.